ค้นหาสินค้า
บริการ
-
Multimeter
-
LCRMeter
-
Spectrum Analyzer
-
Oscilloscope
-
Vector Network Analyzer
-
Function generator
-
Audio Signal Generator
-
Frequency counter
-
RLC Dc Decade Resistance Box
-
Programmable electronic
-
Slide Voltage
-
Lab power supply
-
Clamp on meter
-
Power Analyser
-
Ultrasonic Flow Meter
-
Earth and Soil resistivity
-
Insulation tester
-
milliohm and microohm resistance tester
-
Impulse Winding Tester
-
Safety Tester/Hipot Tester
-
Tachometer Stoboscope
-
Vibration Meter
-
Anemometer
-
Sound meter
-
Lux meter
-
Water Quality Meter
-
Air Environment
-
Hygrometer Thermometer
-
Multifunction / Installation Tester
-
RF Spectrum Analyzer
-
Thermal Image camera
-
Infrared thermometer
-
EMF Spectrum Analyzer
-
Solar cell & Photovoltaic system
-
Calibrator
-
Battery Tester
-
High Voltage Hotline Tools
-
Miscellaneous Meter
-
Trainer Laboratory
-
Transformer Turns Ratio Meter
-
Insulation Oil Tester
-
Accessories
สมัครงาน
ลิ้งก์ภาพ
PIE830 : เครื่องสอบเทียบในกระบวนการผลิต, Milliamp, Voltage, Frequency, pH, Ohms, Thermocouples, RTDs, Pressure, Loop Diagnostics, Transmitter Supply
ข้อมูลสินค้า
-
รหัสสินค้า
PIE 830
-
เข้าชม
352 ครั้ง
ยี่ห้อ
PIE
รุ่น
PIE 830
-
แก้ไขล่าสุดเมื่อ
29/03/2022 10:40
-
รายละเอียดสินค้า
PIE830 : เครื่องสอบเทียบในกระบวนการผลิต, Milliamp, Voltage, Frequency, pH, Ohms, Thermocouples, RTDs, Pressure,
Loop Diagnostics, Transmitter Supply Get more tools in a smaller calibrator Carry eight single function calibrators plus a milliamp calibrator with loop supply plus a loop troubleshooter in the palm of your hand! ▪ Milliamp ▪ Voltage ▪ Frequency ▪ pH ▪ Ohms ▪ Thermocouples ▪ RTDs ▪ Pressure ▪ Loop Diagnostics ▪ Transmitter Supply First calibrator with FIVE troubleshooting tools 1.Detect ‘hidden’ loop problems Quickly diagnose troublesome ground faults & current leakage with patented Loop Diagnostic technology. These problems are undetectable with other instruments! 2.Check all loop parameters at once with the LoopScope™ Simultaneously displays current, voltage and resistance to let you know the condition of a live loop. Finds problems with power supplies & loops with too many loads. Patented by PIE! 3.Automatically detect 2, 3 or 4 wire RTDs Trouble shoot sensor connections and find broken wires with patented technology. LCD indicates which of the four wires are connected to an RTD sensor. 4.Swap out faulty transmitters to diagnose control issues Easily setup the 830 as a universal isolated transmitter for temperature, frequency, millivolt or pressure. If the loop is back under control you know the transmitter was faulty. Turn on the LoopScope to simultaneously see the loop current, power supply voltage and loop loads for troubleshooting. 5.Troubleshoot wiring problems without a multimeter Built in continuity checker with ‘beeper’ quickly finds broken wires or shorts in instrumentation wiring. Also handy for checking operation of relays and controller outputs. The PIE Model 830 is more than a multifunction calibrator. It is also a loop detective that is able to diagnose common problems that other test equipment just can’t find. Have a flooded junction box or unknown ground faults? Our Loop Diagnostic technology will detect it. Or use the LoopScope to see at a glance all the parameters - milliamps, voltage and resistance - in the loop. Stop throwing away perfectly good transmitters only to find the problem is somewhere else in the loop. Setup the PIE Model 830 as an isolated universal transmitter and turn on the Loop Diagnostics. The display will tell you EXACTLY the sensor input, the current output and if there is any uncontrolled current in the loop due to a ground fault, corrosion bridge or moisture. If the control system sees no problem when the 830 is acting as a transmitter THEN you can replace the faulty transmitter. With RTDs the 830 automatically detects which of the 2, 3 or 4 wires are connected and unbroken quickly alerting you to a sensor problem. Diagnostic features are covered by US Patent #7,248,058. Become a troubleshooting technician with Patented Diagnostic Technology - Available only with PIE Calibrators! Typical problem found with Leak Detection Have you ever replaced a “faulty” transmitter only to find the problem was somewhere else in the loop? And did you end up throwing the transmitter away after you fixed the other problem “just in case” the transmitter was faulty? If you find a loop where the transmitter is calibrated correctly but all the readings elsewhere in the loop have a fixed offset this is due to a Zero Shift. This zero shift is typically caused by some current in the loop bypassing the transmitter. This might be caused by ground faults, moisture or corrosion. If you have some loops that are erratic after it rains there may be moisture present in a junction box or where insulation has broken down. Turn on Ground Leak Detection and use the PIE 830 to power up the loop. Any current that isn’t controlled by the transmitter or other current control element will be indicated as leakage on the PIE 830 display. Undetected current leaks may cause calibration errors which can lead to dangerous operating conditions or catastrophic results. The PIE 830 powers up the 2-Wire transmitter or loop and indicates the total current and the uncontrolled current. This provides information useful in troubleshooting loop errors. Become a Loop Detective - Locate hidden loop problems with LoopScope When you need to find out why a loop is out of control and all the wiring seems to be in order turn on the 830’s LoopScope and simultaneously see all the parameters of the loop. The LoopScope simultaneously displays the current, DC voltage and total resistance in the loop. Observing the SUPPLY (DC voltage) and the LOAD (resistance) lets you see if the loop power supply has enough capacity to power all the devices in the loop. By observing all three signals at the same time you can see how the voltage and resistance respond as the current changes. If the voltage drops too far as the current goes up you may need a power supply with more capacity or the power supply itself may be failing. If the resistance in the loop is too high you may have more devices in the loop than the power supply can handle or there may be an instrument in the loop that is drawing too much power and requires replacement. Evolutionary Design ▪ Designed for you by experienced calibrator manufacturers PIE Calibrators are designed and built by members of the same team that designed and built the calibrators manufactured by Fluke* under the Altek* label. The 830 improves upon other brands by including a rubber boot, backlit display with larger digits, troubleshooting tools, higher accuracy and more ranges for flexibility. Ordering Information Included: Four “AA” Alkaline batteries, Certificate of Calibration Blue Rubber Boot .............................................................................................. 020-0213 Evolution Hands Free Carrying Case.................................................................... 020-0211 Evolution mA/V Test Leads................................................................................. 020-0207 1 Red & 1 Black Lead with Banana Plugs & Alligator Clips Evolution RTD Wire Kit....................................................................................... 020-0208 2 Red & 2 Black Leads with Banana Plugs & Spade Lugs Accessories Optional Three Year Repair/Replacement Warranty............................................................ RP-WAR-B Ni-MH 1 Hour Charger with 4 Ni-MH AA Batteries.................................................. 020-0103 (100-120 V AC input for North America Only) Evolution Hands Free Carrying Case with Pressure Module Pocket......................... 020-0233* *This case will be substituted for the Hands Free Case without the Module Pocket (020-0211) when the 830 is ordered with a pressure module Optional Hand Pumps, Tubing & Fitting Kits AP0V 0-300 PSI/20.7 bar Pneumatic Scissor Hand Pump...................................... 020-0224 HP0V 0-3000 PSI/206.9 bar Hydraulic Scissor Hand Pump.................................... 020-0225 DPPV 0-125 PSI/8.6 bar Pressure, 23”/584 mm Hg Vacuum hand pump................. 020-0226 1/8” male NPT x Male Quick-Test™ Fitting with Cap.............................................. 020-0227 Adapter kit (1/8” MNPT&FNPT; 1/4” MNPT, FNPT & Tube Adapter)......................... 020-0228 Quick-Test™ 6900 psi/475 bar hose, 3ft (1 m)....................................................... 020-0229 PKIT1 (020-0224 Pneu Scissor Pump, 020-0229 Hose & 020-0227 fitting)................ 020-0230 PKIT2 (020-0225 Hydr Scissor Pump, 020-0229 Hose & 020-0227 fitting)................ 020-0231 PKIT3 (020-0226 Press/Vac Pump, 020-0229 Hose & 020-0227 fitting).................... 020-0232 Optional Pressure Modules 0-10“/24.9 mbar H20 Differential, Non Isolated................................................... DN0010 0-28“/69.7 mbar H20 Differential, Non Isolated................................................... DN0028 0-200“/498 mbar H20 Differential, Non Isolated.................................................. DN0200 0-415“/1 bar H20 Differential, Non Isolated......................................................... DN0415 0-2000“/5 bar H20 Differential, Non Isolated....................................................... DN2000 0-1 PSI/68.9 mbar Differential, Isolated............................................................... DI0001 0-5 PSI/344.7 mbar Differential, Isolated............................................................. DI0005 0-15 PSI/1 bar Differential, Isolated..................................................................... DI0015 0-30 PSI/2 bar Differential, Isolated..................................................................... DI0030 0-100 PSI/6.9 bar Differential, Isolated................................................................ DI0100 0-300 PSI/20.7 bar Differential, Isolated.............................................................. DI0300 0-500 PSI/34.5 bar Differential, Isolated.............................................................. DI0500 0 to 15 PSI/1 bar Gauge, Isolated...................................................................... GI0015 0 to 30 PSI/2 bar Gauge, Isolated...................................................................... GI0030 0 to 50 PSI/3.4 bar Gauge, Isolated................................................................... GI0050 0 to 100 PSI/6.9 bar Gauge, Isolated................................................................. GI0100 0 to 300 PSI/20.7 bar Gauge, Isolated............................................................... GI0300 0 to 500 PSI/34.5 bar Gauge, Isolated............................................................... GI0500 0 to 1,000 PSI/69 bar Gauge, Isolated............................................................... GI1000 0 to 3,000 PSI/206.8 bar Gauge, Isolated........................................................... GI3000 -14.7 PSIG/1 bar to +15 PSIG/1 bar Compound, Isolated................................... CI0015 -14.7 PSIG/1 bar to +30 PSIG/2 bar Compound, Isolated................................... CI0030 -14.7 PSIG/1 bar to +50 PSIG/3.4 bar Compound, Isolated................................ CI0050 -14.7 PSIG/1 bar to +100 PSIG/6.9 bar Compound, Isolated.............................. CI0100 -14.7 PSIG/1 bar to +300 PSIG/20.7 bar Compound, Isolated............................ CI0300 -14.7 PSIG/1 bar to +500 PSIG/34.5 bar Compound, Isolated............................ CI0500 -14.7 PSIG/1 bar to +1,000 PSIG/69 bar Compound, Isolated............................ CI1000 -14.7 PSIG/1 bar to +3,000 PSIG/ 206.8 bar Compound, Isolated...................... CI3000 0-17 PSIA/1.2 bar Absolute, Isolated.............................................................. AI0017 0-38 PSIA/2.6 bar Absolute, Isolated.............................................................. AI0038 0-100 PSIA/6.9 bar Absolute, Isolated............................................................ AI0100 0-1,000 PSIA/69 bar Absolute, Isolated.......................................................... AI1000 Measure Pressure ▪ Easily measure pressure with a plug in pressure module Purchase any of the pressure modules from the table below along with one of the three hand pumps and tubing kits for a complete pressure calibration system. Media Compatibility Non-isolated DN sensors: clean, dry, non-corrosive, non-condensing gases only Isolated DI sensors: any media compatible with 316L SS & Viton® Isolated GI, CI & AI sensors: any media compatible with 316L SS Accuracy ±0.025% of full scale including all effects of linearity, repeatability and hysteresis from -20° to +50°C (-4° to +122°F) * The DN0010 sensor accuracy is ±0.050% of full scale 32 Engineering Units: PSI • inches, feet, mm, cm and meter of H2O @ 4°C, 20°C & 60°F • inches, meter, cm and mm of Hg @ 0°C; torr • kg/cm2 • kg/m2 • Pa • hPa • kPa • MPa • Bar • mBar • ATM • oz/in2 • lb/ft2 Hand Pumps, Tubing & Fitting Kits ▪ Generate pressure with a full set of hand pumps Choose from a selection hand pumps, tubing & fittings made in the USA by Ralston Instruments. All pumps have two pressure ports - one port & hose go the PIE pressure module and the other to the pressure input of your instrument.