ค้นหาสินค้า
บริการ
-
Multimeter
-
LCRMeter
-
Spectrum Analyzer
-
Oscilloscope
-
Vector Network Analyzer
-
Function generator
-
Audio Signal Generator
-
Frequency counter
-
RLC Dc Decade Resistance Box
-
Programmable electronic
-
Slide Voltage
-
Lab power supply
-
Clamp on meter
-
Power Analyser
-
Ultrasonic Flow Meter
-
Earth and Soil resistivity
-
Insulation tester
-
milliohm and microohm resistance tester
-
Impulse Winding Tester
-
Safety Tester/Hipot Tester
-
Tachometer Stoboscope
-
Vibration Meter
-
Anemometer
-
Sound meter
-
Lux meter
-
Water Quality Meter
-
Air Environment
-
Hygrometer Thermometer
-
Multifunction / Installation Tester
-
RF Spectrum Analyzer
-
Thermal Image camera
-
Infrared thermometer
-
EMF Spectrum Analyzer
-
Solar cell & Photovoltaic system
-
Calibrator
-
Battery Tester
-
High Voltage Hotline Tools
-
Miscellaneous Meter
-
Trainer Laboratory
-
Transformer Turns Ratio Meter
-
Insulation Oil Tester
-
Accessories
สมัครงาน
ลิ้งก์ภาพ
5996-A550-INDUSTRIAL : เครื่องวัดประสิทธิภาพการเผาไหม้ O2,NO,COHigh,NO2,SO2
ข้อมูลสินค้า
-
รหัสสินค้า
5996-A550-INDUSTRIAL
-
เข้าชม
2,320 ครั้ง
ยี่ห้อ
WOEHLER
รุ่น
5996-A550-INDUSTRIAL
-
แก้ไขล่าสุดเมื่อ
30/04/2019 16:25
-
รายละเอียดสินค้า
5996-A550-INDUSTRIAL : เครื่องวัดประสิทธิภาพการเผาไหม้ O2,NO,COHigh,NO2,SO2
Powerfully Tough. Wöhler A 550 INDUSTRIAL Portable Flue gas emissions Analyzer Wöhler A 550 INDUSTRIAL Portable Flue Gas Emissions Analyzer with superior accuracy As tough as cast iron, but as easy to operate as a smartphone – that‘s what Wöhler‘s new Flue Gas Emssions Analyzer feels like in your hand. A tap of your finger on the Wöhler A 550 INDUSTRIAL is all that is required to perform a complete analysis and inspection of boilers and burners. The Flue Gas Emissions Analyzer is designed to be used in tough industrial heat processes. The in-stack stainless steel sinter-filter probe protects the analyzer against heavy dust loads. No matter how you look at it, the new Wöhler A 550 INDUSTRIAL really is a „nifty piece of equipment“: The individual functions can be launched as intuitively as using a smartphone via the large 7" color touchscreen. And the brightly lit monitor can be read anywhere. The large screen, the clear arrangement and the graphical presentation of readings allow excellent readability .„Smart“ handling features Acquiring measurement values is as easy as could be. The analyzer is equipped with magnets, so you can attach it to any magnetic objects to work hands-free. The probe is equipped with a start/stop button to run or hold measurement readings. There are a number of interfaces available to transfer data : USB, infrared and Bluetooth®. And with the Wöhler TD 100 Fast Thermal Printer you can print out the readings on-site. The new battery-driven peltier cooler ensures both accurate NOx and SOx readings and off-grid flexibility. The optional stainless steel sinter-filter protects the device against industrial dust loads. A broad variety of different sample probe lenghts offers the opportunity to take emission measurements in difficult-toreach locations. To measure flue gas velocity and flow rate the Wöhler A 550 INDUSTRIAL is equipped with a dual port digital pressure sensor. S-Tubes and Prandl-probes are available in different length and dimensions. ▪ 7" color-touchscreen as intuitive to use as a smartphone ▪ NOx and SOx emissions measurement with 0,1 ppm resolution ▪ In-stack Sinter-filter probe for dust protection ▪ Battery-driven peltier cooler device - more than 4 h off-grid operation time ▪ High-power sample pump for differential pressures up to 300 mbar ▪ Built-in logger function with user selectable configuration Extensive Range of Functions ▪ Simple to use : Switch on – read off – done ▪ Large, color touchscreen : Displays up to 14 measurement and calculation values ▪ Intuitive to operate via on-screen keyboard ▪ Calibrate in the flue gas pipe via a fresh air pump ▪ Graphic hot spot search extremely reliable ▪ Effective dust and condensate protection ▪ 4-filter technology – easily accessible ▪ Analyzer and sensor diagnostics ▪ Sensor replacement – user-friendly ▪ Rechargeable battery operating time: more than 7 h with Lithium Ion power ▪ Hose assembly – robust and flexible huge range of applications ▪ Expandable with up to 5 sensors ▪ For measurements: NO, NO2, SO2 ▪ Probe for a variety of measurement tasks ▪ In-stack sinter-filter for heavy dust loaded samples simple data management ▪ 1,000 measurement records ▪ Data transfer via USB, Bluetooth or infrared TÜV-Approved ▪ DIN EN 50379 Part 2 Technical data Oxygen concentration (O2) in flue gas Display Volume % referenced to dry flue gas Volume % referenced to dry flue gas Measurement principle Electrochemical sensor Range 0.0-21.0 vol. % Accuracy ± 0.3 vol.-% Carbon monoxide (CO 100,000) in flue gas Display Volume ppm referenced to dry flue gas Measurement principle Electrochemical sensor Range 0-100,000 vol. ppm; resolution 1 vol. ppm Accuracy ± 100 vol. ppm (< 1,000 vol. ppm), otherwise 10% of reading (with H2 < 5 % of reading) Nitric oxide concentration (NO) in flue gas Display Volume ppm referenced to dry flue gas Measurement principle Electrochemical sensor Range 0-3,000 vol. ppm (continuously up to 1,000); resolution 0.1 vol. ppm (< 1,000 vol. ppm), otherwise 1 vol. ppm Accuracy ± 5 vol. ppm (< 100 vol. ppm), otherwise 5 % of reading Nitrogen dioxide concentration (NO2) in flue gas Display Volume ppm referenced to dry flue gas Measurement principle Electrochemical sensor Range 0-1,000 vol. ppm (continuously up to 200 vol. ppm); resolution 0.1 vol. ppm Accuracy ±5 vol. ppm (< 100 ppm), otherwise 5% of reading Sulfur dioxide concentration (SO2) in flue gas Display Volume ppm referenced to dry flue gas Measurement principle Electrochemical sensor Range 0-5,000 vol. ppm; resolution 0.1 vol. ppm (< 1,000 vol. ppm), otherwise 1 vol. ppm Accuracy ±10 vol. ppm (< 200 vol. ppm), otherwise 5% of reading Differential pressure (PD) Display Pascal Measurement principle Semi-conductor diaphragm Range 0.00 to ± 110.00 hPa; resolution 0.1 Pa (< 1,000 Pa), otherwise 1 Pa Accuracy 0.3 Pa (< 10.0 Pa), otherwise 3% of reading Flue gas temperature (TS) Display °C Measurement principle Thermocouple (NiCr-Ni) (NiCr-Ni) Range -20.0 °C to 800 °C; resolution 0.1 °C Accuracy 0-133 °C: ± 2°C 133-800 °C: ± 1.5 % of reading Combustion air temperature (TA) Display °C Measurement principle Thermocouple (NiCr-Ni) Range -20.0 °C to 100 °C; resolution 0.1 °C Accuracy ± 1°C Power supply Lithium-Ion, rechargeable battery 3.7 V, 5800 mAh, charges via USB Battery operating time Approx. 7 h (depends on operating status and display illumination) Storage temperature -20 °C to +50 °C Operating temperature +5-40 °C to maintain stated accuracy Weight 1,250 g
Tags : WOEHLER , 5996-A550-INDUSTRIAL , เครื่องวัดประสิทธิภาพการเผาไหม้ , Flue Gas Analyzer , 5996-A550-INDUSTRIAL , WOEHLER , เครื่องวิเคราะห์ก๊าซ , เครื่องวิเคราะห์แก๊ส , เครื่องวัดประสิทธิภาพการเผาไหม้ , เครื่องวัดประสิทธิภาพการเผาไหม้และแก๊ส , Gas Analyser , Flue Gas Analyser , Com