ค้นหาสินค้า
บริการ
-
Multimeter
-
LCRMeter
-
Spectrum Analyzer
-
Oscilloscope
-
Vector Network Analyzer
-
Function generator
-
Audio Signal Generator
-
Frequency counter
-
RLC Dc Decade Resistance Box
-
Programmable electronic
-
Slide Voltage
-
Lab power supply
-
Clamp on meter
-
Power Analyser
-
Ultrasonic Flow Meter
-
Earth and Soil resistivity
-
Insulation tester
-
milliohm and microohm resistance tester
-
Impulse Winding Tester
-
Safety Tester/Hipot Tester
-
Tachometer Stoboscope
-
Vibration Meter
-
Anemometer
-
Sound meter
-
Lux meter
-
Water Quality Meter
-
Air Environment
-
Hygrometer Thermometer
-
Multifunction / Installation Tester
-
RF Spectrum Analyzer
-
Thermal Image camera
-
Infrared thermometer
-
EMF Spectrum Analyzer
-
Solar cell & Photovoltaic system
-
Calibrator
-
Battery Tester
-
High Voltage Hotline Tools
-
Miscellaneous Meter
-
Trainer Laboratory
-
Transformer Turns Ratio Meter
-
Insulation Oil Tester
-
Accessories
สมัครงาน
ลิ้งก์ภาพ
JUPITER : ดิจิตอลมัลติมิเตอร์ AC+DC TRMS voltage, RCD, THD, Earth, Loop, Inrush
ข้อมูลสินค้า
-
รหัสสินค้า
JUPITER
-
เข้าชม
3,302 ครั้ง
ยี่ห้อ
HT ITALIA
รุ่น
JUPITER
-
แก้ไขล่าสุดเมื่อ
29/04/2019 14:21
-
รายละเอียดสินค้า
JUPITER : ดิจิตอลมัลติมิเตอร์ AC+DC TRMS voltage, RCD, THD, Earth, Loop, Inrush
MULTIMETER & MULTIFUNCTION Technical specifications DC Voltage Measurement range: 0.0V ÷ 690.0V Resolution: 0.1V Accuracy: ±(0.5%reading + 2digits) AC TRMS, DC, AC+DC TRMS, LoZ Voltage Measurement range: 0.5V ÷ 690.0V Frequency range: 32Hz ÷ 1kHz Resolution: 0.1V Accuracy: ±(0.5%reading + 2digits) AC TRMS Current with Flexible clamp F3000U Measurement range: 1A ÷ 3000A Basic resolution: 0.01A Accuracy: ±(0.5%reading + 2digits) AC TRMS, DC, AC+DC TRMS Current with Standard clamp Measurement range: 1mV ÷ 1000mV Resolution: 1mV Accuracy: ±(0.5%reading + 2digits) Inrush current (DIRC) - Flexible clamp F3000U Measurement range: 1A ÷ 3000A Basic resolution: 0.01A Frequency range: 42.5Hz ÷ 69Hz Accuracy: ±(2.0%reading + 2digits) Peak response time: 1ms Max RMS response times: 16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms Inrush current (DIRC) - Standard clamp Measurement range: 1mV ÷ 1000mV Resolution: 1mV Frequency range: 42.5Hz ÷ 69Hz Accuracy: ±(2.0%reading + 2digits) Peak response time: 1ms Max RMS response times: 16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms Resistance and Continuity test Measurement range: 0.0Ω ÷ 1999Ω Basic resolution: 0.1Ω Accuracy: ±(1.0%reading + 5digits) Buzzer sound: R<30Ω Voltage / Current Harmonics Harmonic order: DC, 1st ÷ 25th + THD% Frequency range: 42.5Hz ÷ 69Hz Resolution: 0.1V / 0.1A Basic accuracy: ±(5.0%reading + 10digits) Phase rotation test with 1-wire method Measurement range: 100V ÷ 690V Frequency range: 42.5Hz ÷ 69Hz L-N, L-L, L-PE Loop / Line Impedance L-PE, L-N voltage range: 100V ÷ 690V Frequency range: 42.5Hz ÷ 69Hz Test current: 100mA Measurement range: 0.1Ω ÷ 199.9Ω Basic accuracy: ±(5.0%reading + 3digits) Test on RCD protection devices RCD type: AC, A, General Trip-out time measurement (ms) / Trip-out current measurement (mA) L-PE voltage range: 100V ÷ 690V Frequency range: 42.5Hz ÷ 69Hz Trip-out time measurement: IΔN selectable among 30mA, 100mA, 300mA Trip-out current measurement for IΔN of 30mA Overall earth resistance without RCD tripping L-PE voltage range: 100V ÷ 690V Frequency range: 42.5Hz ÷ 69Hz Test current: <15mA Measurement range: 1Ω ÷ 1999Ω Resolution: 1Ω Accuracy: 5.0%reading + 3Ω General specifications General characteristics Instrument safety: IEC/EN61010-1, IEC/EN61010-2-030, IEC/EN61010-2-033 EMC: IEC/EN61326-1 RCD test: IEC/EN61557-6 Loop L-L, L-N, L-PE, Ra test: IEC/EN61557-3 Phase rotation test: IEC/EN 61557-7 Insulation: double insulation Pollution degree: 2 Measurement category: CAT IV 600V, CAT III 690V to ground and between inputs Mechanical characteristics Dimensions (L x W x H): 175 x 85 x 55mm Weight (batteries included): 420g Mechanical protection: IP40 Power supply Battery type: 4x1.5V alkaline type AAA IEC LR03 Auto Power OFF: after15min of idleness Display Display type: 4 LCD, max 9999 counts, sign, decimal point backlight and bargraph, polarity indication Frequency rate: 2times/s Optional accessories ▪ F3000U AC flexible clamp with 30/300/3000A full scales ▪ HT96U* AC current clamp with 1/100/1000A full scales ▪ HT97U* AC current clamp with 10/100/1000A AC full scales ▪ HT98U* DC current clamp with 1000A full scale ▪ HT4006 AC/DC current clamp with 40/400A full scales ▪ NOCANBA Hypertac-to-banana adapter Standard accessories ▪ C2065 Three wire cable Red, Black, Green with Shuko plug ▪ 4324-2 Pair of test tips Red/Black 2/4mm straight banana ▪ YABAT0001HT0 Alkaline battery 1.5V, type AAA, IEC LR03, 4 pcs ▪ YABRS0002HT0 Carrying bag ▪ YAMUM0066HT0 User manual on CD-ROM ▪ YAMUM0065HT0 Quick reference guide ▪ Calibration certificate ISO9000 You might think I am just a multimeter Autorange measurements with automatic AC/DC detection. DC, AC TRMS, AC+DC TRMS voltage up to 690V. Low impedance voltage input to eliminate ghost voltage readings. DC, AC TRMS, AC+DC TRMS current by means of external transducer. Frequency of voltage and/or current. Resistance and continuity with buzzer. MIN/MAX/PEAK/HOLD functions. 6000 counts. My name is Jupiter. Why to choose me? Just because I am out of this world. I am the only multimeter capable of testing the electrical installation safety. I compare each measure with the limits provided by the guidelines, so to provide a clear OK / NOT OK result. My functions are available on high-end instruments only. I allow a wide range of external transducers to measure AC TRMS, DC, AC+DC, and inrush current. I am Portable, Rugged and Compact. but I have a multifunction soul! RCD tripping time and current: full control! RCD tripping time and current. ▪ I can measure the tripping time of RCDs type A and AC up to 300mA and the tripping current of RCDs type AC up to 30mA (RAMP test). ▪ My AUTO function makes everything more immediate: my display will show you the 6 consecutive tests (x1/2,x1, x2, x5, 0°, 180°) for a full RCD check. ▪ I will show you an unequivocal response OK or NOT OK. ELECTRICAL SPECIFICATIONS Accuracy calculated as [%reading + (num. dgt* resolution)] at 23°C 5°, <80%HR Accuracy of harmonics amplitudes expressed in % is evaluated considering the accuracy of parameters ratio (*) Harmonic voltages are zeroed in the followed conditions: ▪ 1° harmonic: value <0.5V ▪ DC, 2° to 25° harmonics: harmonic value <0.5% fundamental value or value <0.5V (*) Harmonic currents are zeroed in the followed conditions: ▪ 1° harmonic: value <0.5A ▪ DC, 2° to 25° harmonics: harmonic value <0.5% fundamental value or value <0.5A
Tags : HT ITALIA , JUPITER , ดิจิตอลมัลติมิเตอร์ , มัลติมิเตอร์ , DMM AC+DC TRMS voltage , เครื่องมือวัด