ค้นหาสินค้า
บริการ
-
Multimeter
-
LCRMeter
-
Spectrum Analyzer
-
Oscilloscope
-
Vector Network Analyzer
-
Function generator
-
Audio Signal Generator
-
Frequency counter
-
RLC Dc Decade Resistance Box
-
Programmable electronic
-
Slide Voltage
-
Lab power supply
-
Clamp on meter
-
Power Analyser
-
Ultrasonic Flow Meter
-
Earth and Soil resistivity
-
Insulation tester
-
milliohm and microohm resistance tester
-
Impulse Winding Tester
-
Safety Tester/Hipot Tester
-
Tachometer Stoboscope
-
Vibration Meter
-
Anemometer
-
Sound meter
-
Lux meter
-
Water Quality Meter
-
Air Environment
-
Hygrometer Thermometer
-
Multifunction / Installation Tester
-
RF Spectrum Analyzer
-
Thermal Image camera
-
Infrared thermometer
-
EMF Spectrum Analyzer
-
Solar cell & Photovoltaic system
-
Calibrator
-
Battery Tester
-
High Voltage Hotline Tools
-
Miscellaneous Meter
-
Trainer Laboratory
-
Transformer Turns Ratio Meter
-
Insulation Oil Tester
-
Accessories
สมัครงาน
ลิ้งก์ภาพ
SDM3065X : TRMS ดิจิตอลมัลติมิเตอร์แบบตั้งโต๊ะ, ความละเอียด 6 1/2 หลัก AC/DC voltage, AC/DC current, 2/4-wire resistance, capacitace, diode
ข้อมูลสินค้า
-
รหัสสินค้า
SDM3065X
-
เข้าชม
1,992 ครั้ง
ยี่ห้อ
SIGLENT
รุ่น
SDM3065X
ลิงค์
http://www.evertech.co.th/product-category/194083/Multimeter.html
-
แก้ไขล่าสุดเมื่อ
29/04/2019 14:20
-
รายละเอียดสินค้า
SDM3065X : TRMS ดิจิตอลมัลติมิเตอร์แบบตั้งโต๊ะ, ความละเอียด 6 1/2 หลัก AC/DC voltage, AC/DC current, 2/4-wire resistance,
capacitace, diode Product Overview
SDM3065X is a 6 ½ digit digital (2,200,000 count) multimeter incorporating a dual –display and is especially well suited for the needs of high-precision, multifunction and automatic measurement. Application fields Research Laboratory ▪ Research Laboratory ▪ Development Laboratory ▪ Detection and Maintenance ▪ Calibration Laboratory ▪ Automatic Production Test Main Function Basic Measurement Function ▪ DC Voltage: 200 mV ~ 1000 V ▪ DC Current: 200 μA ~ 10 A ▪ AC Voltage: True-RMS, 200 mV ~ 750 V ▪ AC Current: True-RMS, 200 μA ~ 10 A ▪ 2/4-Wire Resistance: 200Ω ~ 100 MΩ ▪ Capacitance: 2 nF ~ 100 mF ▪ Continuity Test: Range is fixed at 2 kΩ ▪ Diode Test: Adjustable range is 0 ~ 4V. ▪ Period Measurement: 1 μs ~ 333.33 ms ▪ Temperature: Support for TC and RTD sensor Math Function Max, Min, Average, Standard Deviation,dBm/dB, Relative Measurement ,Pass/Fail Histogram, Trend Chart, Bar Meter, etc. Main Feature ▪ 4.3” TFT-LCD, 480*272 ▪ Real 6½ digits readings resolution (2,200,000 counts) ▪ 1Gb Nand flash size, Mass storage configuration files and data files ▪ True-RMS AC Voltage and AC Current measuring ▪ Support double display, Chinese and English Menu ▪ File management (support for U-disc and local storage) ▪ Built-in cold terminal compensation for thermocouple ▪ With easy, convenient and flexible any sensor measurement control software: EasyDMM ▪ Standard interface: USB Device, USB Host, LAN (Optional Accessories: GPIB and Scanner Card) ▪ Built-in help system makes information acquisition more easier ▪ Support remote control via commands and compatible with commands of main stream multimeters Special Features Remarks: [1] Specifications are for 90-minute warm-up and 100NPLC integration time. For integration time <100NPLC, add the appropriate “RMS Noise Adder” listed in the following table. [2] 10% over range on all ranges except DCV 1000V and DCI 10A range. [3] Relative to calibration standards. [4] For each additional volt over ± 500 V, add 0.03mV error. [5] For continuous current > 7A DC or 7A AC RMS, 30 seconds ON and 30 seconds OFF. [6] Specifications are for 4–wire resistance measurement or 2–wire resistance measurement using REL operation. Without REL operation , add 0.2 Ω additional error in 2-wire resistance measurement. [7] Accuracy specifications for the voltage measured at the input terminal only. 1 mA test current is typical. Variation in the current source will create some variation in the voltage drop across a diode junction. Adjustable voltage range : 0~ 4V. Remarks: [1] Typical value. Resolution is defined as the typical 20V range RMS noise. [2] Normal mode rejection ratio for power-line frequency ± 0.1%. For power-line frequency ± 1%, subtract 20 dB. For ± 3%, subtract 30dB. [3] Maximum rate for DCV, DCI, 2-wire resistance and 4-wire resistance functions. [4] The basic DC accuracy specifications include RMS noise at 100 NPLC. For <100 nplc="" add="" rms="" noise="" adder="" to="" the="" basic="" dc="" td=""> accuracy specifications. [5] When Power Supply of frequency is 60Hz, the cycles is 0.006, 0.06, 0.6,1,10,100 NPLC. Remarks: [1] Specifications are for 90-minute warm-up, > 3Hz ac filter and sine wave input. [2] 10% over range on all ranges except ACV 750 V and ACI 10 A ranges. [3] Relative to calibration standards. [4] Specifications are for sine wave input >5% of range. For inputs within 1% and 5% of range and <50 khz="" add="" 0="" 1="" of="" range="" additional="" td=""> error. For 50 kHz to 100k Hz, add 0.13% of range additional error. [5] ACV 750 range limited to 8x107 Volt-Hz. For input over 300V rms, add 0.7mV error for each additional volt. [6] For continuous current > DC 7A or AC RMS 7A, 30 seconds ON and 30 seconds OFF. [7] For frequency blow 100 Hz, the specification of slow filter is only for sine wave input. [8] Specifications are for sine wave input >5% of range. For inputs within 1% to 5% of range, add 0.1% of range additional error. Specifications are typical values for 200uA and 2mA, 2A and 10A ranges when frequency >1k Hz. Remarks: [1] Specifications are for 90 minutes warm-up. Exclusive of sensor error. [2] Specification is for 4WR sensor measurement or 2WR measurement using REL operation. [3] Relative to cold junction temperature, accuracy is based on ITS-90. Built-in cold junction temperature refers to the temperature inside the banana jack and its accuracy is ± 2.5 . Remarks: [1] 20 V range, 1k Hz input. [2] The measurement period changes with the capacitance under test.
Tags : SIGLENT , SDM3065X , มัลติมิเตอร์ , ดิจิตอลมัลติมิเตอร์ , Digital Multimeter